Feature | DATCOM | DATCOMplus | DATCOMplus Zone 2 |
---|---|---|---|
Material | Glass fiber polycarbonate | same | same |
Dimension (approx.) | 8.3 x 7.5 x 3.7 in | 10.4 x 7.9 x 4.4 in | 10.4 x 7.9 x 4.4 in |
Weight (basic) | 3.3lbs | 4.85lbs | 5.0lbs |
Protection Class | IP66, outdoor enviroment | same | same |
Working Temperature | -13F to +158F (-40F to +158F optional) | same | -13F to +140F |
Keypad | 6 button capacitive keypad | same | 6 button capacitive keypad |
Display | Graphic backlit LCD 128 x 64 | same | same |
Display (-40F variant) | Alphanumeric segment backlit LCD | same | not available |
Transducers | max. 2 (3 w. Slot-0 EDTport module) | max. 6 (w. Slot-0 Ext1 + Ext1/T module) | max. 4 |
P. Transducer Ranges (low) | 0 - 2.9; 0 - 14.5; 0 - 23.2; 0 - 58; 0 - 87; 0 - 145 | same | same |
P. Transducer Ranges (high) | 0 - 362.6; 0 - 580.2; 0 - 1015.3 | same | same |
T. Transducers | -13 ºF to +158 ºF (opt. -40 ºF to +158 ºF) | same | -13 ºF to +158 ºF |
Digital Inputs (std. LF) | max. 2 (LF or Binary) | max. 4 (LF or Binary) | max. 4 (LF or Binary) |
Digital Inputs (HF) | not available | max. 4 (w. Slot-0 Ext1/HF module) | max. 4 |
Digital Outputs | max 2 (LF or Binary) | max. 4 (LF or Binary) | max. 4 (LF or Binary) |
Analog I/Os (4-20mA) | not available | max. 6 (Slot-1 2AI or 2AO, 2x AI w. Ext1+Ext/t modules) | max. 6 (Slot-1 2AI or 2AO, 2x AI w. Ext1+Ext/t modules) |
Add. Digital I/Os | not available | max. 8 (LF, Binary; In or Output) | not available |
Comm. Port (front) | 1x optical interface | same | same |
Comm. Ports (internal) | 1x RS232/485 | max. 2 RS232/485 (Slot-1/2 COM module) | max. 2 RS232/485 (Slot-1/2 COM module) |
Modem | 1x internal (Slot-4 LTE-Cat1 module) | same | same |
Battery | Single Battery Pack or Holder (up to 10yrs.) * | Single or Double Battery Pack or Holder (10-15yrs)* | Single Battery Pack or Holder (for backup only) |
External Power | not available | 5 VDC (Slot-3 PWR1 module) | 12/24VDC, 120VAC (Slot-4: PWR4, PWR3) |
External Power - Modem | not available | 5 VDC (Slot-4 PWR2 module) | powered by ext. power module in Slot-4 |
Mounting | Pipe or Wall | Pipe or Wall | Pipe or Wall |