top of page
Feature
ELCOR
ELCORplus
ELCORplus Zone 2
ELCORplus Indexer
Material

Glass fiber polycarbonate

same

same

same

Dimension (approx.)

8.3 x 7.5 x 3.7 in

10.4 x 7.9 x 4.4 in

10.4 x 7.9 x 4.4 in

10.4 x 10.6 x 5.2 in

Weight (basic)

3.3lbs

4.85lbs

5.0lbs

5.35lbs

Protection Class

IP66, outdoor enviroment

same

same

same

Working Temperature

-13F to +158F (-40F to +158F optional)

same

-13F to +140F

same

Keypad

6 button capacitive keypad

same

6 button capacitive keypad

same

Display

Graphic backlit LCD 128 x 64

same

same

same

Display (-40F variant)

Alphanumeric segment backlit LCD

same

not available

same

Transducers

max. 2 (3 w. Slot-0 EDTport module)

max. 6 (w. Slot-0 Ext1 + Ext1/T module)

max. 4

max. 4

P. Transducer Ranges (low)

0 - 2.9; 0 - 14.5; 0 - 23.2; 0 - 58; 0 - 87; 0 - 145

same

same

same

P. Transducer Ranges (high)

0 - 362.6; 0 - 580.2; 0 - 1015.3

same

same

same

T. Transducers

-13 ºF to +158 ºF  (opt. -40 ºF to +158 ºF)

same

-13 ºF to +158 ºF

same

Digital Inputs (std. LF)

max. 2 (LF or Binary)

max. 4 (LF or Binary)

max. 4 (LF or Binary)

max. 2 (LF or Binary)

Digital Inputs (HF)

not available

max. 4 (w. Slot-0 Ext1/HF module)

max. 4

not available

Add. Digital I/Os

not available

max. 8 (LF, Binary; In or Output)

not available

not available

Mech. Instrument Drive

not available

not available

not available

1x (CW or CCW selectable)

Meter Runs

max. 1

max. 3

max. 3

max. 2 (1x mech. Instrument Drive, 1x LF pulses)

Digital Outputs

max 2 (LF or Binary)

max. 4 (LF or Binary)

max. 4 (LF or Binary)

max. 4 (LF or Binary)

Analog I/Os (4-20mA)

not available

max. 6 (Slot-1 2AI or 2AO, 2x AI w. Ext1+Ext/t modules)

max. 6 (Slot-1 2AI or 2AO, 2x AI w. Ext1+Ext/t modules)

max. 4 (Slot-1 2AI or 2AO module)

Comm. Port (front)

1x optical interface

same

same

same

Comm. Ports (internal)

1x RS232/485

max. 2 RS232/485 (Slot-1/2 COM module)

max. 2 RS232/485 (Slot-1/2 COM module)

max. 2 RS232/485 (Slot-1/2 COM module)

Modem

1x internal (Slot-4 LTE-Cat1 module)

same

same

same

Battery

Single Battery Pack or Holder (up to 10yrs.) *

Single or Double Battery Pack or Holder (10-15yrs)*

Single Battery Pack or Holder (for backup only)

Single or Double Battery Pack or Holder (10-15yrs)*

External Power

not available

5 VDC (Slot-3 PWR1 module)

12/24VDC, 120VAC (Slot-4: PWR4, PWR3)

5 VDC (Slot-3 PWR1 module)

External Power - Modem

not available

5 VDC (Slot-4 PWR2 module)

powered by ext. power module in Slot-4

5 VDC (Slot-4 PWR2 module)

Mounting

Pipe or Wall

Pipe or Wall

Pipe or Wall

gas meter Instrument Drive

Elcor
ElcorPlus Indexer
ElcorPlud
ElcorPlus Zone 2
*) Battery life is depending on hardware and software configuration.
bottom of page